Reading Your Result
For MPPT controllers, the result is a current rating in amps. It's the array watts divided by battery voltage, with a 25 percent safety margin, rounded up to the next standard size. Above 100 A, the practical choice is several controllers sharing the array.
The second check is voltage. A controller's max PV rating is a hard limit, and panels make their highest voltage on the coldest morning. If cold Voc comes out above the controller rating, you need fewer panels in each series string or a higher-rated controller.
How It's Calculated
MPPT amps = array W ÷ battery V × 1.25
PWM amps = Isc × parallel strings × 1.25
Cold Voc = Voc × series × (1 + |coef %| ÷ 100 × (25 − lowest °C)), minimum series Vmp ≥ charge V + 5
Worked Examples
Worked example · Brazil, MPPT on a 24 V bank
The array is 3 panels in series, each 400 W, so 1,200 W total. The battery is 24 V.
Current = 1,200 ÷ 24 × 1.25 = 50 × 1.25 = 62.5 A, which rounds up to 80 A.
Each panel has Voc 41 V and a −0.29 percent per °C coefficient. At a 5°C low, the factor is 1 + 0.0029 × 20 = 1.058.
Cold Voc = 41 × 3 × 1.058 = 130.1 V, below a 150 V limit. An 80 A, 150 V controller fits.
Charge voltage is 28.8 V for a 24 V bank, so the series Vmp needs 33.8 V or more. Three panels at 34 V give 102 V.
Worked example · Kenya, PWM on a 12 V bank
The array is 2 parallel strings of 12 V panels, each with Isc 9.5 A.
Current = 9.5 × 2 × 1.25 = 19 × 1.25 = 23.75 A.
Rounding up gives a 30 A PWM controller.
PWM needs panels with a nominal voltage close to the battery, so use 12 V nominal panels here.
Common Mistakes
- Sizing by panel watts divided by 12 V when the battery is actually 24 V or 48 V.
- Checking the controller against Voc at 25°C instead of the cold Voc.
- Pairing a PWM controller with high-voltage grid-style panels. The mismatch wastes most of the output.
- Ignoring the controller's own max PV watts rating for the battery voltage chosen.