Inverter Size Calculator With Surge

Find the inverter that runs your AC loads together and survives motor start-up. Enter the appliances that run at the same time and any start-up multipliers.

Reading Your Result

The continuous rating comes from the AC watts that run at once, plus a 25 percent margin. Add only what runs simultaneously. A load that never overlaps with the others doesn't need to be counted again.

The surge figure matters for motors, pumps, and compressors, which pull several times their running power for a moment. Compare the surge needed with the inverter's peak rating on its datasheet. The DC input current tells you how big your battery cables and fuses must be.

How It's Calculated

Formula

Continuous W = simultaneous AC running W × 1.25

Continuous rating. Round up to 300, 600, 1000, 1500, 2000, 3000, 4000, 5000, 6000, 8000, or 10000 W.
Formula

Surge W = largest start surge (W × multiplier) + other simultaneous running W

Surge needed. Other running watts means everything on at the time except the load that is starting.
Formula

DC amps = continuous W ÷ (system V × 0.92)

DC input current. Use this number to size battery cables and the main fuse.

Worked Examples

Worked example · Pakistan, home with a water pump

Running together are a fridge at 150 W, three fans at 75 W each (225 W), lights at 60 W, and a pump at 750 W. Total = 1,185 W.

Continuous = 1,185 × 1.25 = 1,481 W, which rounds up to 1,500 W.

The pump has a start multiplier of 3, so its surge is 750 × 3 = 2,250 W.

Surge needed = 2,250 + (1,185 − 750) = 2,250 + 435 = 2,685 W.

On a 24 V system, DC amps = 1,500 ÷ (24 × 0.92) = 1,500 ÷ 22.08 = 67.9 A.

Worked example · Australia, off-grid workshop

Running together are a circular saw at 1,400 W, lights at 120 W, and a radio at 30 W. Total = 1,550 W.

Continuous = 1,550 × 1.25 = 1,937.5 W, which rounds up to 2,000 W.

The saw has a start multiplier of 2, so its surge is 1,400 × 2 = 2,800 W.

Surge needed = 2,800 + (1,550 − 1,400) = 2,800 + 150 = 2,950 W.

On a 48 V system, DC amps = 2,000 ÷ (48 × 0.92) = 2,000 ÷ 44.16 = 45.3 A.

Common Mistakes

  • Adding every appliance in the house instead of the ones that run at the same time.
  • Skipping the surge check for a pump, compressor, or air conditioner.
  • Choosing a low-voltage inverter for a large load, which forces very heavy battery cable.
  • Treating a modified sine wave inverter as safe for every motor and electronic charger.

Frequently Asked Questions

How do I find an appliance's start-up multiplier?

Check the label or manual for locked rotor or start current. When it's missing, a common planning range is 2 to 3 for fridges and small pumps, and higher for some compressors.

Is a bigger inverter always safer?

It adds headroom, but it also draws more idle power every hour and costs more. Match the size to the load list and avoid large oversizing.

What does the 1.25 margin cover?

It keeps the inverter from running at its limit, which lowers heat and extends its life. It also leaves room for small loads you forgot.

Pure sine or modified sine?

Pure sine works with nearly everything, including motors, medical devices, and variable-speed tools. Modified sine can cause buzzing, extra heat, and failures in some equipment.

Why is DC input current so high?

Low battery voltage means more amps for the same watts. Moving to 24 V or 48 V cuts the current to a half or a quarter.

Do I need a fuse between the battery and inverter?

Yes, as close to the battery as practical, sized to your wire and local electrical code. The wire size calculator on this site gives a starting fuse value.

Related Calculators and Guides

Results are estimates based on typical values and the settings above. Local electrical codes apply, and a qualified installer should check the final design before you buy or wire anything. Read the full disclaimer.