Reading Your Result
The result is run time, not fuel. It shows how many hours the generator must work to make up the shortfall between your monthly load and your monthly solar production. A zero means solar covers the month by itself.
Winter months and cloudy spells drive the number up. Check the worst month and think about whether a larger array, a bigger battery, or fewer loads costs less over time than more generator hours. The 0.85 factor accounts for the generator's output after charger and wiring losses.
How It's Calculated
Hours per month = max(0, monthly load kWh − monthly production kWh) ÷ (generator kW × 0.85)
Production kWh = installed W × sun hours × 0.80 × days ÷ 1000
Worked Examples
Worked example · Norway, cabin in December
Monthly load is 150 kWh and the array makes 40 kWh in December.
Shortfall = 150 − 40 = 110 kWh.
A 3 kW generator delivers 3 × 0.85 = 2.55 kW.
Hours = 110 ÷ 2.55 = 43.1 hours for the month.
Worked example · Brazil, cloudy month on a farm
Daily load is 12 kWh, so a 30-day month needs 12 × 30 = 360 kWh.
A 3,000 W array with 3.0 peak sun hours makes 3,000 × 3.0 × 0.80 × 30 ÷ 1000 = 216 kWh.
Shortfall = 360 − 216 = 144 kWh.
A 5 kW generator delivers 5 × 0.85 = 4.25 kW, so hours = 144 ÷ 4.25 = 33.9 hours.
Common Mistakes
- Planning for the average month and forgetting that the worst month needs the most generator time.
- Choosing a generator much larger than the charging path can use, which wastes fuel at light load.
- Skipping generator service and fuel storage rules. Check your local code for safe placement and exhaust clearance.
- Running a generator inside a closed space. Exhaust carries carbon monoxide, so always run it outdoors with good airflow.