Solar Glossary
Short, plain definitions with an example for each term.
- AGM Battery
- A sealed lead-acid battery with glass mat separators that needs no watering and handles moderate cycling.
- Amp-Hours
- A unit of battery capacity showing how many amps a battery can supply for how many hours.
- AWG (American Wire Gauge)
- The US system for labeling wire thickness, where a smaller number means thicker wire.
- Battery Bank
- A group of batteries wired together to store the energy an off-grid system needs overnight and in bad weather.
- BMS (Battery Management System)
- An electronic board that monitors a lithium battery and shuts it down before voltage, current, or temperature go unsafe.
- Charge Controller
- A device that regulates power from solar panels to protect the battery from overcharging.
- Days of Autonomy
- The number of days a battery bank can run your loads with no solar input.
- Depth of Discharge
- The share of a battery's capacity that a system uses before recharging, shown as a percentage.
- Derate
- A reduction factor applied to rated output to account for real-world losses such as heat, dust, and wiring.
- Imp (Current at Maximum Power)
- The current a solar panel delivers at its maximum power point under standard test conditions.
- Inverter
- A device that converts DC power from batteries or panels into AC power for standard appliances.
- Isc (Short-Circuit Current)
- The maximum current a solar panel produces when its output is shorted, used to size fuses and wiring.
- Kilowatt-Hour
- A unit of energy equal to 1,000 watt-hours, the same unit used on utility bills.
- LiFePO4
- Lithium iron phosphate, a long-lasting battery chemistry with high usable capacity and good safety.
- Load Shedding
- Turning off nonessential loads to protect battery charge and stretch runtime.
- Modified Sine Wave
- A stepped, blocky AC waveform from low-cost inverters that suits simple loads but not all electronics.
- MPPT
- Maximum power point tracking, a charge controller method that converts extra panel voltage into extra charging current.
- Parallel Wiring
- Connecting panels or batteries positive to positive and negative to negative so current adds up and voltage stays the same.
- Peak Sun Hours
- The number of hours per day that sunlight averages 1,000 watts per square meter at a given site.
- Pure Sine Wave
- An inverter output that matches the smooth AC power from the utility grid.
- PWM
- Pulse width modulation, a basic charge controller type that pulls panel voltage down to match the battery.
- Round-Trip Efficiency
- The share of energy put into a battery that comes back out when the battery discharges.
- Series Wiring
- Connecting panels or batteries positive to negative so voltage adds up and current stays the same.
- Solar Array
- A group of solar panels wired together to produce the power for an off-grid system.
- State of Charge
- The amount of energy left in a battery, shown as a percentage of its full capacity.
- String Sizing
- Choosing how many panels to wire in series so the string voltage fits the charge controller's limits.
- Surge Watts
- The brief burst of power a device draws at startup, often several times its running wattage.
- Temperature Coefficient
- The percent change in a solar panel's voltage or power for every degree Celsius away from 25 °C.
- Vmp (Voltage at Maximum Power)
- The voltage at which a solar panel delivers its rated power under standard test conditions.
- Voc (Open-Circuit Voltage)
- The highest voltage a solar panel produces with no load connected, listed on its datasheet.
- Voltage Drop
- The loss of voltage along a wire caused by its resistance, shown as a percentage of system voltage.
- Watt-Hours
- A unit of energy equal to one watt used or produced for one hour.