Offgrid Atlas

Solar Glossary

Short, plain definitions with an example for each term.

AGM Battery
A sealed lead-acid battery with glass mat separators that needs no watering and handles moderate cycling.
Amp-Hours
A unit of battery capacity showing how many amps a battery can supply for how many hours.
AWG (American Wire Gauge)
The US system for labeling wire thickness, where a smaller number means thicker wire.
Battery Bank
A group of batteries wired together to store the energy an off-grid system needs overnight and in bad weather.
BMS (Battery Management System)
An electronic board that monitors a lithium battery and shuts it down before voltage, current, or temperature go unsafe.
Charge Controller
A device that regulates power from solar panels to protect the battery from overcharging.
Days of Autonomy
The number of days a battery bank can run your loads with no solar input.
Depth of Discharge
The share of a battery's capacity that a system uses before recharging, shown as a percentage.
Derate
A reduction factor applied to rated output to account for real-world losses such as heat, dust, and wiring.
Imp (Current at Maximum Power)
The current a solar panel delivers at its maximum power point under standard test conditions.
Inverter
A device that converts DC power from batteries or panels into AC power for standard appliances.
Isc (Short-Circuit Current)
The maximum current a solar panel produces when its output is shorted, used to size fuses and wiring.
Kilowatt-Hour
A unit of energy equal to 1,000 watt-hours, the same unit used on utility bills.
LiFePO4
Lithium iron phosphate, a long-lasting battery chemistry with high usable capacity and good safety.
Load Shedding
Turning off nonessential loads to protect battery charge and stretch runtime.
Modified Sine Wave
A stepped, blocky AC waveform from low-cost inverters that suits simple loads but not all electronics.
MPPT
Maximum power point tracking, a charge controller method that converts extra panel voltage into extra charging current.
Parallel Wiring
Connecting panels or batteries positive to positive and negative to negative so current adds up and voltage stays the same.
Peak Sun Hours
The number of hours per day that sunlight averages 1,000 watts per square meter at a given site.
Pure Sine Wave
An inverter output that matches the smooth AC power from the utility grid.
PWM
Pulse width modulation, a basic charge controller type that pulls panel voltage down to match the battery.
Round-Trip Efficiency
The share of energy put into a battery that comes back out when the battery discharges.
Series Wiring
Connecting panels or batteries positive to negative so voltage adds up and current stays the same.
Solar Array
A group of solar panels wired together to produce the power for an off-grid system.
State of Charge
The amount of energy left in a battery, shown as a percentage of its full capacity.
String Sizing
Choosing how many panels to wire in series so the string voltage fits the charge controller's limits.
Surge Watts
The brief burst of power a device draws at startup, often several times its running wattage.
Temperature Coefficient
The percent change in a solar panel's voltage or power for every degree Celsius away from 25 °C.
Vmp (Voltage at Maximum Power)
The voltage at which a solar panel delivers its rated power under standard test conditions.
Voc (Open-Circuit Voltage)
The highest voltage a solar panel produces with no load connected, listed on its datasheet.
Voltage Drop
The loss of voltage along a wire caused by its resistance, shown as a percentage of system voltage.
Watt-Hours
A unit of energy equal to one watt used or produced for one hour.