Depth of Discharge

The share of a battery's capacity that a system uses before recharging, shown as a percentage.

What It Means

Depth of discharge, or DoD, is the percentage of a battery's rated capacity that gets used in a cycle. A 50% DoD means half the capacity is drawn out before recharging. Batteries last longer when discharged less deeply, so each type has a recommended limit. LiFePO4 batteries handle about 90% DoD. Lead-acid batteries, including AGM, work best at about 50%. The limit matters because it decides how big the battery bank must be. A lower DoD means more nameplate capacity for the same usable energy.

Example

A 12 V, 100 Ah battery stores 1,200 Wh. At 50% DoD, a lead-acid version gives 600 Wh of usable energy. A LiFePO4 version at 90% DoD gives 1,080 Wh before efficiency losses. The LiFePO4 battery delivers 480 Wh more from the same nameplate size.