Reading Your Result
Series wiring adds voltage and keeps current the same. Parallel wiring adds current and keeps voltage the same. The goal is a string voltage high enough to charge the battery and low enough to stay under the controller's limit on the coldest day.
Read the result in three parts. The minimum series count keeps the array above battery charging voltage, the maximum series count comes from cold Voc, and the number of parallel strings sets the total current. If the minimum and maximum don't leave room for your panel count, a different controller or panel is the fix.
How It's Calculated
Max series = floor(controller max PV ÷ (Voc × (1 + |coef %| ÷ 100 × (25 − lowest °C))))
Series Vmp ≥ charge V + 5, where charge V ≈ 14.4 × (battery V ÷ 12)
Array Vmp = Vmp × series, array current = Imp × parallel strings
Worked Examples
Worked example · Kenya, six panels on a 48 V bank
Each panel is 300 W with Voc 39 V, Vmp 32 V, Imp 9.4 A, and a −0.29 percent per °C coefficient. The controller limit is 150 V and the lowest temperature is 10°C.
Cold factor = 1 + 0.0029 × (25 − 10) = 1.0435, so cold Voc per panel = 39 × 1.0435 = 40.7 V.
Max series = 150 ÷ 40.7 = 3.68, which means 3 panels. Three panels give 122.1 V cold.
Min series for 48 V = 57.6 + 5 = 62.6 V. Two panels give 64 V, so 2 or 3 in series both work.
Six panels wire as 3 in series × 2 in parallel. Array Vmp = 96 V and current = 2 × 9.4 = 18.8 A.
Worked example · Norway, four panels on a 24 V bank
Each panel is 400 W with Voc 41.5 V, Vmp 34 V, Imp 11.76 A, and a −0.27 percent per °C coefficient. The controller limit is 150 V and the lowest temperature is −25°C.
Cold factor = 1 + 0.0027 × 50 = 1.135, so cold Voc per panel = 41.5 × 1.135 = 47.1 V.
Max series = 150 ÷ 47.1 = 3.18, which means 3 panels. Four in series would reach 188.4 V, so that fails.
Min series for 24 V = 28.8 + 5 = 33.8 V, so 1 panel is enough in theory, but 2 in series gives more headroom.
Wire as 2 in series × 2 in parallel. Cold Voc = 94.2 V, Vmp = 68 V, and current = 2 × 11.76 = 23.5 A.
Common Mistakes
- Calculating maximum series from Voc at 25°C instead of the coldest expected temperature.
- Paralleling strings with different panel types, which drags the stronger string down.
- Skipping string fuses or breakers when three or more strings run in parallel. Check local code for the exact rule.
- Forgetting that wire and combiner box ratings must cover the higher parallel current.