Reading Your Result
One peak sun hour means 1 kWh of sunlight energy per square meter in an hour. NASA POWER's ALLSKY_SFC_SW_DWN value, in kWh/m²/day, equals peak sun hours directly. It's a long-term monthly average, so any single week may run higher or lower.
Read the monthly chart for seasons. A big gap between the best and worst month means a year-round system must be sized for the worst one, or backed by a generator. The calculator also turns each month's value into expected kWh for your array size.
How It's Calculated
Peak sun hours = irradiation in kWh/m²/day
Design sun = lowest monthly value, array W = daily Wh ÷ (design sun × 0.80)
kWh = installed W × sun hours × 0.80 × days ÷ 1000
Worked Examples
Worked example · South Africa, average versus worst month
Suppose a site has 4.0 peak sun hours in the worst month, June, and a higher yearly average of 5.5. The load is 3,000 Wh per day.
Sizing on the average gives 3,000 ÷ (5.5 × 0.80) = 3,000 ÷ 4.4 = 682 W.
In June, that 682 W array makes 682 × 4.0 × 0.80 = 2,182 Wh, only 73 percent of the daily need.
Sizing on the worst month gives 3,000 ÷ (4.0 × 0.80) = 3,000 ÷ 3.2 = 938 W, which covers June.
Worked example · Norway, summer against winter
Assume 5.0 peak sun hours in June and 0.6 in December for a 1,000 W array.
June, 30 days = 1,000 × 5.0 × 0.80 × 30 ÷ 1000 = 120 kWh.
December, 31 days = 1,000 × 0.6 × 0.80 × 31 ÷ 1000 = 14.9 kWh.
June makes about 8 times more energy than December, so a year-round system here needs a generator or a very large array.
Common Mistakes
- Using a single yearly average for a system that must run in winter.
- Mixing units and treating MJ/m²/day as if it were already kWh/m²/day.
- Treating a long-term average as a guarantee for any given week.
- Reading sun hours as daylight hours. A 12-hour day can hold only 4 or 5 peak sun hours.