Offgrid Atlas

String Sizing

Choosing how many panels to wire in series so the string voltage fits the charge controller's limits.

What It Means

String sizing is the process of deciding how many panels go in one series string. The string must stay inside the charge controller's voltage window. At the top, the cold Voc of the whole string must stay below the controller's maximum input. At the bottom, the hot-weather Vmp must stay above the controller's minimum working voltage. Cold Voc = Voc × series × (1 + |coef%| ÷ 100 × (25 − lowest temperature in C)). Getting this wrong can destroy a controller or leave panels idle.

Example

A controller allows 100 V maximum. Each panel has a Voc of 22.5 V, a coefficient of −0.30%/°C, and the site's low is −10 °C. Three panels give 22.5 × 3 × 1.105 = 74.6 V, which is safe. Four panels give 99.5 V, too close to the limit.