Take the inverter's continuous watts, work out the DC amps it pulls from the battery, multiply by 1.25, and round up to the next standard size. A 2,000 W inverter on a 24 V bank pulls 90.6 A, which gives 113.2 A, so you'd fit a 125 A fuse. Here's the full method, a lookup table, and what the cable has to do.
How Many Amps Does the Inverter Pull?
An inverter loses some power as heat, so the battery supplies more than the AC output. The site uses 92 percent efficiency.
Inverter DC input A = continuous W ÷ (system V × 0.92)
Use the inverter's continuous rating, not the surge rating. If you're still choosing one, the inverter size calculator and the guide to choosing the right inverter size come first. The inverter glossary page covers the basics.
Standard sizes in amps are 1, 2, 3, 5, 7.5, 10, 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 100, 125, 150, 175, 200, 225, 250, 300, and 400.
What Size Fuse for Each Inverter and Battery Voltage?
This table covers common sizes. Amps show two decimals, and the fuse is picked from the unrounded 1.25 figure.
| Inverter | System V | DC input A | Times 1.25 | Fuse size | | --- | --- | --- | --- | --- | | 1,000 W | 12 V | 90.58 A | 113.22 A | 125 A | | 1,000 W | 24 V | 45.29 A | 56.61 A | 60 A | | 1,000 W | 48 V | 22.64 A | 28.31 A | 30 A | | 2,000 W | 12 V | 181.16 A | 226.45 A | 250 A | | 2,000 W | 24 V | 90.58 A | 113.22 A | 125 A | | 2,000 W | 48 V | 45.29 A | 56.61 A | 60 A | | 3,000 W | 12 V | 271.74 A | 339.67 A | 400 A | | 3,000 W | 24 V | 135.87 A | 169.84 A | 175 A | | 3,000 W | 48 V | 67.93 A | 84.92 A | 100 A |
Higher voltage means lower current, thinner cable, and a smaller fuse. A 2,000 W inverter on 12 V needs a 250 A fuse, and a 3,000 W unit needs 400 A. Both are beyond the largest 232 A cable in the metric table. That's a sign to move to 24 V or 48 V. The battery bank size calculator helps you pick a voltage.
Where Does the Fuse Go?
Put it in the positive cable, as close to the battery positive terminal as practical. The fuse protects the cable. If it sits far from the battery, the cable between the two has no protection, and a short there can melt insulation fast.
Wire the fuse in line with the positive run before it reaches the inverter or any bus bar. Keep the holder tight and clean, because a loose connection heats up even when the current is normal.
Does the Wire Match the Fuse?
The fuse protects the wire, so the wire must carry at least the fuse rating. Check ampacity against the site's wire tables.
| Metric size | Ampacity | AWG size | Ampacity | | --- | --- | --- | --- | | 10 mm2 | 57 A | 6 AWG | 65 A | | 16 mm2 | 76 A | 4 AWG | 85 A | | 25 mm2 | 101 A | 2 AWG | 115 A | | 35 mm2 | 125 A | 1 AWG | 130 A | | 50 mm2 | 150 A | 1/0 AWG | 150 A | | 70 mm2 | 192 A | 2/0 AWG | 175 A | | 95 mm2 | 232 A | 4/0 AWG | 230 A |
A 125 A fuse needs 35 mm2 or 1 AWG at minimum, and many installers go one size up when the wire is already at its rating. Ampacity is only half the job, since a long run also loses voltage. Use the solar wire size calculator and read up on voltage drop and AWG. On the panel side, see what size fuse between solar panels and the charge controller. For cable runs, the wire from the charge controller to the battery and wire from solar panels to the charge controller guides pick up from here.
Worked Example in Pakistan
Worked example · 1,000 W Inverter in Faisalabad
A home backup system uses a 1,000 W inverter on a 12 V battery.
DC input = 1,000 ÷ (12 × 0.92) = 1,000 ÷ 11.04 = 90.58 A.
Fuse minimum = 1.25 × 90.58 = 113.22 A, which rounds up to 125 A.
The cable must carry 125 A or more. 35 mm2 does that at exactly 125 A, and 1 AWG covers it at 130 A. A 25 mm2 cable at 101 A sits under the fuse rating, so a fault could overheat it before the fuse acts.
Worked Example in Norway
Worked example · 3,000 W Inverter at a Cabin in Telemark
A cabin runs a 3,000 W inverter on a 48 V lithium bank.
DC input = 3,000 ÷ (48 × 0.92) = 3,000 ÷ 44.16 = 67.93 A.
Fuse minimum = 1.25 × 67.93 = 84.92 A, which rounds up to 100 A.
25 mm2 carries 101 A and 2 AWG carries 115 A, so either passes the ampacity check for a 100 A fuse. The same inverter on 12 V would need a 400 A fuse. The 48 V bank keeps both the fuse and the cable small.
Why Use a Class T or ANL Fuse?
A big battery can push thousands of amps into a dead short. A basic blade or glass fuse may not stop that, and the arc can keep going. Lithium banks are the hard case, since they can deliver very high current very fast.
A Class T fuse is built for this. It's fast, and it's rated to interrupt very high DC current, so it clears a hard short in a fraction of a second. An ANL fuse is a bolt-on bar type common on mid-size systems, and it suits banks where the available short-circuit current is lower. Check the fuse's interrupt rating against your battery's maximum short-circuit current, which is on the battery datasheet. Pick a fuse rated above that figure.
Fuse or Breaker?
Both work if they're DC-rated at your battery voltage. A fuse is faster and simpler. A breaker can switch the inverter off for service, and it resets without a spare part. Many builders fit a fuse close to the battery and a DC breaker or switch near the inverter. Never use an AC breaker on a DC circuit, since it can't stop DC arcs. Make sure the breaker's interrupt rating is high enough for your bank.
Before you buy, confirm these points.
- Inverter DC amps use continuous watts, system volts, and 0.92 efficiency
- Fuse is 1.25 × DC amps, rounded up
- Fuse sits as close to the battery positive terminal as practical
- Wire ampacity is at least the fuse rating
- Fuse or breaker is DC-rated, with a high interrupt rating