Offgrid Atlas

What Size Fuse Between Solar Panels and the Charge Controller

6 min read · Published 2026-11-17 · Last updated 2026-11-17 · Offgrid Atlas Editorial

For most arrays, the fuse between your panels and the charge controller is 1.25 times the short-circuit current of one string, rounded up to the next standard size. A string with an Isc of 10 A needs a 12.5 A minimum, so you'd fit a 15 A fuse. This guide shows the math, when you can skip the fuse, and what voltage rating the fuse needs.

What Size Fuse Do You Need on Each String?

Each string of panels gets its own fuse. Size it from the Isc printed on the panel label or datasheet. Panels in series share the same current, so the Isc of one panel is the Isc of the string.

Formula

PV string fuse A = 1.25 × Isc of one string

Round up to the next standard size, never down.

Standard fuse sizes in amps are 1, 2, 3, 5, 7.5, 10, 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 100, 125, 150, 175, 200, 225, 250, 300, and 400. If the result lands exactly on a size, use that size.

| Panel Isc | Times 1.25 | Fuse size | | --- | --- | --- | | 8.5 A | 10.63 A | 15 A | | 10.0 A | 12.50 A | 15 A | | 11.5 A | 14.38 A | 15 A | | 13.9 A | 17.38 A | 20 A | | 18.0 A | 22.50 A | 25 A |

The extra 25 percent covers days when the sun is stronger than the panel's test rating, and it keeps normal current from slowly heating the fuse. Some local codes use a larger safety factor, so check yours before you buy.

Do I Even Need a Fuse?

Not always. A string fuse guards against backfeed. If one string shorts, the other strings can push their current back into it. With one or two strings, the other string can't push enough current to hurt a panel or wire.

  • 2 strings or fewer in parallel. A string fuse is often not needed, so check the max series fuse rating on the panel datasheet and your local code
  • 3 strings or more in parallel. Fit a fuse on every string, usually in an inline MC4 fuse holder or a combiner box

A single string wired straight to the controller usually doesn't need one. The battery side still needs protection, and the battery to inverter fuse guide covers that part. For more on how strings combine, read series vs parallel solar panel wiring.

Does a PV Fuse Need a Voltage Rating?

Yes, and it's the part people miss. A fuse on the PV side must be DC-rated. An AC fuse can't stop a DC arc, which keeps burning once it starts.

The fuse also needs a voltage rating at least as high as the string's cold open-circuit voltage. Panels make their highest voltage on a cold, bright morning. Run your numbers through the cold Voc calculator. If the cold Voc of a string comes to 118 V, a fuse rated 150 V DC or higher is the right pick. A 32 V automotive fuse isn't.

The Vmp is the voltage on a normal day, but it's not the number to use here. Always use cold Voc for the fuse voltage.

Worked Example in Pakistan

Worked example · Four Strings on a Rooftop in Multan

A rooftop array has four strings in parallel. Each panel lists an Isc of 13.9 A.

Four strings is more than two, so every string gets a fuse.

Fuse = 1.25 × 13.9 = 17.375 A, which rounds up to 20 A.

The panel datasheet lists a max series fuse rating of 25 A, so 20 A sits under the limit.

Four 20 A DC-rated fuses in MC4 fuse holders or a combiner box protect the array. The main cable to the controller can see up to 4 × 13.9 = 55.6 A of short-circuit current, so size that run with the solar wire size calculator. The guide on wire from solar panels to the charge controller has the steps.

Worked Example in Kenya

Worked example · Three Strings at a Clinic Near Kisumu

A small clinic has three strings in parallel. Each panel lists an Isc of 9.8 A.

Fuse = 1.25 × 9.8 = 12.25 A, which rounds up to 15 A.

Three strings means a fuse on each one. If the clinic later cut the array to two strings, the fuses might not be needed, but the datasheet and local code should settle that.

The next check is cold Voc. If each string comes to 90 V when cold, a 150 V DC fuse works. Pick the voltage rating that matches your own string, not a number from this example.

Where Does the Fuse Go?

Put the fuse in the positive conductor, close to the array end of the run. Many installers fuse both poles in larger systems, but one pole is the common minimum. Fuse holders get warm, so keep them out of direct sun and tight corners.

Match the wire to the fuse. The cable must carry at least the fuse rating, so the fuse protects the wire and not the other way round. A 15 A fuse on 1.5 mm2 cable is fine, since that cable is good for 16 A. A 20 A fuse on 1.5 mm2 is not. In AWG terms, a 20 A fuse needs 14 AWG or larger, which carries 20 A. Many installers go one size up when the wire is already at its rating, if it fits the run. See AWG and voltage drop for cable sizing, and check the controller side in wire from the charge controller to the battery.

Fuse or Breaker on the PV Side?

A DC-rated breaker can do the same job as a fuse, and it lets you switch the array off for service. Size it with the same 1.25 rule. A breaker can trip at a lower current on a hot day than its label says, so leave a little room. A fuse is cheaper and has no moving parts, but you have to replace it after it pops.

AC breakers from a home panel are not a stand-in. They aren't built to break DC current at array voltage.

Quick Checklist

  • Fuse rating is 1.25 × string Isc, rounded up to a standard size
  • Fuse sits at or under the panel's max series fuse rating
  • Fuse is DC-rated, with a voltage rating above the string's cold Voc
  • Wire ampacity is at least the fuse rating
  • You checked your local code for a larger safety factor

To plan the whole array, try the solar panel series-parallel calculator or the charge controller calculator. The MPPT vs PWM guide explains how the controller you pick affects string voltage, and the off-grid planner ties it all together.

Related Calculators and Guides

Results are estimates based on typical values and the settings above. Local electrical codes apply, and a qualified installer should check the final design before you buy or wire anything. Read the full disclaimer.